- Quilt[4]
- Solar Energy Systems[3]
- Alternative Energy Generators[3]
- Street Lights[7]
- Solar Cells[2]
- Plastic Tubes[10]
- Rubber Hoses[5]
- Sterilization Equipments[10]
- Other Machinery[10]
- Wicker Crafts[10]
- Wrench[1]
- Other Lifting Tools[2]
- Other Auto Parts[8]
- Contact Person : Ms. Guan Helen
- Company Name : China National Huachen Energy Group Co., Ltd.
- Tel : 86-531-81675010
- Fax : 86-531-87928195
- Address : Shandong,Jinan,Floor 7th, Fengli Building, No. 318, Quancheng Road
- Country/Region : China
- Zip : 250021
Floor standing horizontal autoclave
TMQ.CV-5070 model is fully automatic, suitable for treatment to low density materials as dressing, hollow instruments as dental drillers of low and high speed and etc in operating rooms, department of stomatology and ophthalmology, laboratory biological research and medical institutions.
Major capability and characteristics
² Controlled by PLC with touch keys.
² The built-in imported vacuum pump capable of exhausting air thoroughly from dressings, loading bags and the hollow dental drillers with a vacuum degree of –0.09Mpa.
² The high penetration of the steam ensures a a complete sterilization.
² The post vacuum drying system providing a –0.095Mpa degree of vacuum with a residue humidity of no more than 0.2% after drying.
² Equipped with B/D test program, vacuum test program, vacuum leakage proportion less than 0.133Kpa/min.
² 0.2μm air filter ensures sterile air in, preventing inside chamber from recontamination.
² Stages, temperature and time of processes displayed dynamically on the crystal screen also with failure indication system by self-checking.
² There are equipped with 4 sterilization programs for customer’s choice.
² The buzzer alarms when a cycle of operation is completed.
² Capable of killing HIV and HBS virus.
Safety devices
² Auto protection device against over temperature This system cuts off power automatically if the designed temperature is surpassed.
² Door safety interlock The door cannot be opened until there is no pressure in the chamber and power for heating cannot be switched on until the door is firmly closed.
² Safety valve of auto release against overpressure It opens when the designed pressure is surpassed.
² Auto protection against overpressure: When working pressure surpasses the design value, there will be auto steam relief to release pressure with alarm
² Water shortage protection: Power to the heating element is cut off automatically with alarm when water level is lower than the bottom limit in the steam generator.
² Vacuum pump overload protection: Thermal protection relay will act with alarm when there is an overload on the vacuum pump.
² Vacuum pump water shortage protection: Vacuum pump will be stopped automatically with alarm when there is a lack of water.
² Electro circuit safety device: there is a protection device for short circuit in the main AC circuit, and a device against over voltage and overload in the DC control circuit.
Major technical parameters
u Designed pressure -0.21- 0.26Mpa Designed temperature 150°C
u The most working pressure 0.23Mpa The most working temperature 132°C
u Choice of sterilization temperature within 121°C~134°C, temperature equitability in the chamber ≤±0.5°C
u Time relay 0-60 minutes
u Water source Pure or distilled
u Vacuum pump water source 0.1—0.15MPa
u Chamber make-up SUS 304
u Air exhausted from the chamber after 3 times pulse vacuum ≥99.9%
u Standard allocation: 2 shelves stainless steel trays
u Chamber size Φ500×700 (mm) Valid capacity 135 liters
u Packing dimension W800×H1700×L980
u Power source 380V 50Hz 8 Kw
Floor standing horizontal autoclave