Floor standing horizontal autoclave

Floor standing horizontal autoclave
Product Detailed
Related Categories:Sterilization Equipments
Authorized the certificates of ISO9001,13485 and EN46001

A small size autoclave with rapid function by means of high temperature pressure steame for treatment to sugical instruments, dressing, glass utensils, injection sets, liquor and etc in operating rooms, department of stomatology and ophthalmology, biological research and medical institutions.

   Major capability and characteristics

² Controlled by microcomputer with touch keys.

² Water feeding, heating, sterilization, steam exhaust, drying controlled automatically in a cycle.

² Temperature and time of process as well as working stages displayed dynamically on the crystal screen. Self-failure test system capable of displaying failure on the crystal screen.

² There are equipped with 5 sterilization programs and 2 self-defining programs for customer’s choice.

² The buzzer alarms when a cycle of operation is completed.

² Equipped with pre-heating function.

Safety devices

² Auto protection device against over temperature This system cuts off power automatically if the designed temperature is surpassed.

² Door safety interlock The door cannot be opened until there is no pressure in the chamber and power for heating cannot be switched on until the door is firmly closed.

² Safety valve of auto release against overpressure It opens when the designed pressure is surpassed.

² Water absence protection device  Power for heating is cut off automatically when water level in the chamber is lower than the bottom level.

² Electrical safety device: protection device against over-voltage and overload for DC power, protection device against short circuit for the mains current cable. 

Major technical parameters

u Designed pressure     0.26Mpa  

u  Designed temperature    150°C

u Rated working pressure   0.23Mpa

u Rated working temperature   135°C

u Choice of sterilization temperature within  105°C~136°C

u Time relay within: 0-60 minutes

u Chamber size  Φ500×D950 mm ( 

u Dimension  1250x710x1700mm (LxWxH)

u Packing size: 1380x890x1830mm (LxWxH)

u Valid capacity   185 liters

u Power source  380V  50Hz  10.8 Kw

u Wright: net/gross 220/250 Kg