China National Huachen Energy Group Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Guan Helen
  • Company Name : China National Huachen Energy Group Co., Ltd.
  • Tel : 86-531-81675010
  • Fax : 86-531-87928195
  • Address : Shandong,Jinan,Floor 7th, Fengli Building, No. 318, Quancheng Road
  • Country/Region : China
  • Zip : 250021

Tabletop autoclave

Tabletop autoclave
Product Detailed
Related Categories:Sterilization Equipments
Authorized the certificates of ISO9001 and EN46001 Won European CE certificate

A small size Class-B autoclave with rapid function by means of high temperature pressure steam in accordance with latest international standard prEN13060

   Suitable for treatment to low density materials (dressing and etc), hollow surgical instruments (high and low speed hand driller) and etc in operating rooms, department of stomatology and ophthalmology, biological research and medical institutions.

   Major capability and characteristics

² Controlled by PLC with touch keys.

² Built-in vacuum pump capable of vacuuming thoroughly inside dressings and bags, also the dental hand-driller under a vacuum condition of –0.09 Mpa by three times vacuuming, thus a thorough sterilization is guaranteed.

² Post-vacuum drying system offering a result of humidity less than 0.2% with a vacuum condition of –0.095Mpa.    

² Equipped with B/D test, vacuum test programs offering a result of less than 0.133Kpa/min.

² The 0.2μm filter provides sterile air into the chamber preventing a recontamination.

² Temperature and time of process as well as working stages displayed dynamically on the crystal screen.

² Self-failure test system capable of displaying failure on the crystal screen.

² There are equipped with 4 sterilization programs for customer’s choice.

² The buzzer alarms when a cycle of operation is completed.

² Capable of killing HIV and HBS virus.

Safety devices

² Auto protection device against over temperature This system cuts off power automatically if the designed temperature is surpassed.

² Door safety interlock The door cannot be opened until there is no pressure in the chamber and power for heating cannot be switched on until the door is firmly closed.

² Safety valve of auto release against overpressure It opens when the designed pressure is surpassed.

Major technical parameters

u Designed pressure   0.26Mpa  

u  Designed temperature  150°C

u The most working pressure  0.22Mpa  

u Choice of sterilization temperature within  121°C~134°C temperature uniformity in the chamber is  ≤±0.5°C)

u Water requirement  Pure or distilled 

u Chamber size  Φ380×500 (mm)  

u Valid capacity  60 liters

u Power source  380V  50Hz  5.6Kw

u Packing size  985x736x676mm

Tabletop autoclave



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.